Woodward 8237-1599

← Woodward Obsolete Part Finder

ProTech-GII – Panel Mount, HV/HV, Independent Relays (non-preferred) · ProTech-GII Overspeed Protection
Non-Preferred

Still supported, but Woodward has designated it non-preferred. Plan a move to the preferred model.

Ask Drake about repair / overhaul of your existing unit.

Drake-recommended replacement

Direct replacement.

Preferred itemDescriptionApplies when
8237-2599ProTech-GII – Panel Mount, HV/HV, Ind. Relays (current Preferred part number)For new installations; same mount/voltage/relay configuration. The Non-Preferred PN remains available for spares and existing installations. Existing Rev D or newer units can be converted with kit 8929-039; units older than Rev D require factory conversion (PCN 06946).
Note: Declared Non-Preferred as of June 2018: available for spares or existing installations, but should not be used for new installations (Rev H p.2). Field Software Conversion Kit 8929-039 converts Rev D or newer units to the current model; older units require factory conversion (PCN 06946). See 8237-2599 for the current preferred model.

Lifecycle facts

Woodward part number8237-1599
Product familyProTech-GII Overspeed Protection
Lifecycle statusNon-Preferred
Sourcemanual 35086; manual 51582; kit 8929-039; service tool 9927-1810; ProTech-GII TPS MSM Support Statement rev H p.2
Cross-reference confidenceConfirmed from the cited Woodward publication

Source: PCN 06946, Rev A

✓ Sourced directly from the cited Woodward publication — Drake confirms the exact part before quoting

One of Woodward’s largest global channel partners Founded 2002. A Score Group company. Authorized Woodward Distributor & Woodward RTR/RER

Check any other Woodward part number in the Obsolescence Finder, or browse the full cross-reference directory.